ISO 286 tolerance and fit calculator
Enter a nominal size and a hole class, a shaft class or both to get the limit deviations, the limits and, for a pair, the fit.
| Class | H7 | g6 |
|---|---|---|
| Upper deviation | +21 µm | -7 µm |
| Lower deviation | 0 µm | -20 µm |
| Tolerance | 21 µm | 13 µm |
| Maximum size | 25.021 mm | 24.993 mm |
| Minimum size | 25 mm | 24.98 mm |
Clearance fit
Maximum clearance: 41 µm
Minimum clearance: 7 µm
A negative clearance is an interference.
Calculated in your browser: the values you enter are never sent anywhere.
How it works
A tolerance class is a letter and a number. The letter, the fundamental deviation, places the tolerance zone relative to the nominal size; the number, the standard tolerance grade IT, sets its width. Capital letters are holes and lowercase letters are shafts.
In a fit, the clearance is the hole size minus the shaft size. If it is always positive the fit has clearance; if it is always negative, interference; if it can be either, it is a transition fit.
Rule
Maximum size = nominal + upper deviation; minimum size = nominal + lower deviation; tolerance = upper − lower deviation. Maximum clearance = ES − ei; minimum clearance = EI − es.
Worked example
Ø25 H7/g6: H7 gives ES = +21 µm and EI = 0; g6 gives es = −7 µm and ei = −20 µm. Maximum clearance = 21 − (−20) = 41 µm and minimum clearance = 0 − (−7) = 7 µm. Both are positive, so it is a clearance fit.
Frequent fits
Each fit has its own page with the limits, the fit type and its typical use.
- H11/c11
- H9/d9
- H8/f7
- H7/g6
- H7/h6
- H7/k6
- H7/n6
- H7/p6
- H7/s6
- H7/u6
Values from ISO 286-1:2010, ISO 286-2:2010. For reference only: the drawing and the standard govern.