Ø10 H9/d9 fit

Ø10 H9/d9 is a clearance fit: the clearance runs from 40 to 112 µm.

Clearance fit

Limits

Deviations and limits of size of Ø10 H9/d9
ClassHole H9Shaft d9
Upper deviation+36 µm-40 µm
Lower deviation0 µm-76 µm
Tolerance36 µm36 µm
Maximum size10.036 mm9.96 mm
Minimum size10 mm9.924 mm

Maximum size = nominal + upper deviation; minimum size = nominal + lower deviation; tolerance = upper − lower deviation. Maximum clearance = ES − ei; minimum clearance = EI − es.

Open Ø10 H9/d9 in the calculator

Typical use

Free running fit where accuracy is not essential, or for high speeds, heavy journal pressures or large temperature changes.

A guide only: the final choice depends on materials, temperatures, lengths and finishes.