Skip to content
Vectogap
Español

Ø10 H7/s6 fit

Ø10 H7/s6 is an interference fit: the interference runs from 8 to 32 µm.

Interference fit

Limits

Deviations and limits of size of Ø10 H7/s6
ClassHole H7Shaft s6
Upper deviation+15 µm+32 µm
Lower deviation0 µm+23 µm
Tolerance15 µm9 µm
Maximum size10.015 mm10.032 mm
Minimum size10 mm10.023 mm

Maximum size = nominal + upper deviation; minimum size = nominal + lower deviation; tolerance = upper − lower deviation. Maximum clearance = ES − ei; minimum clearance = EI − es.

Open Ø10 H7/s6 in the calculator

Typical use

Medium drive fit for ordinary steel parts or shrink fits on light sections. Usually the tightest fit used with cast iron.

A guide only: the final choice depends on materials, temperatures, lengths and finishes.

Values from ISO 286-1:2010, ISO 286-2:2010. For reference only: the drawing and the standard govern.