Skip to content
Vectogap
Español

Ø20 H7/s6 fit

Ø20 H7/s6 is an interference fit: the interference runs from 14 to 48 µm.

Interference fit

Limits

Deviations and limits of size of Ø20 H7/s6
ClassHole H7Shaft s6
Upper deviation+21 µm+48 µm
Lower deviation0 µm+35 µm
Tolerance21 µm13 µm
Maximum size20.021 mm20.048 mm
Minimum size20 mm20.035 mm

Maximum size = nominal + upper deviation; minimum size = nominal + lower deviation; tolerance = upper − lower deviation. Maximum clearance = ES − ei; minimum clearance = EI − es.

Open Ø20 H7/s6 in the calculator

Typical use

Medium drive fit for ordinary steel parts or shrink fits on light sections. Usually the tightest fit used with cast iron.

A guide only: the final choice depends on materials, temperatures, lengths and finishes.

Values from ISO 286-1:2010, ISO 286-2:2010. For reference only: the drawing and the standard govern.