Ø20 H7/s6 fit
Ø20 H7/s6 is an interference fit: the interference runs from 14 to 48 µm.
Interference fit
Limits
| Class | Hole H7 | Shaft s6 |
|---|---|---|
| Upper deviation | +21 µm | +48 µm |
| Lower deviation | 0 µm | +35 µm |
| Tolerance | 21 µm | 13 µm |
| Maximum size | 20.021 mm | 20.048 mm |
| Minimum size | 20 mm | 20.035 mm |
Maximum size = nominal + upper deviation; minimum size = nominal + lower deviation; tolerance = upper − lower deviation. Maximum clearance = ES − ei; minimum clearance = EI − es.
Open Ø20 H7/s6 in the calculatorTypical use
Medium drive fit for ordinary steel parts or shrink fits on light sections. Usually the tightest fit used with cast iron.
A guide only: the final choice depends on materials, temperatures, lengths and finishes.
Values from ISO 286-1:2010, ISO 286-2:2010. For reference only: the drawing and the standard govern.