Ø16 H7/s6 fit
Ø16 H7/s6 is an interference fit: the interference runs from 10 to 39 µm.
Interference fit
Limits
| Class | Hole H7 | Shaft s6 |
|---|---|---|
| Upper deviation | +18 µm | +39 µm |
| Lower deviation | 0 µm | +28 µm |
| Tolerance | 18 µm | 11 µm |
| Maximum size | 16.018 mm | 16.039 mm |
| Minimum size | 16 mm | 16.028 mm |
Maximum size = nominal + upper deviation; minimum size = nominal + lower deviation; tolerance = upper − lower deviation. Maximum clearance = ES − ei; minimum clearance = EI − es.
Open Ø16 H7/s6 in the calculatorTypical use
Medium drive fit for ordinary steel parts or shrink fits on light sections. Usually the tightest fit used with cast iron.
A guide only: the final choice depends on materials, temperatures, lengths and finishes.
Values from ISO 286-1:2010, ISO 286-2:2010. For reference only: the drawing and the standard govern.