Ø16 H7/h6 fit
Ø16 H7/h6 is a clearance fit: the clearance runs from 0 to 29 µm.
Clearance fit
Limits
| Class | Hole H7 | Shaft h6 |
|---|---|---|
| Upper deviation | +18 µm | 0 µm |
| Lower deviation | 0 µm | -11 µm |
| Tolerance | 18 µm | 11 µm |
| Maximum size | 16.018 mm | 16 mm |
| Minimum size | 16 mm | 15.989 mm |
Maximum size = nominal + upper deviation; minimum size = nominal + lower deviation; tolerance = upper − lower deviation. Maximum clearance = ES − ei; minimum clearance = EI − es.
Open Ø16 H7/h6 in the calculatorTypical use
Locational clearance fit: a snug fit for locating stationary parts that can still be assembled and taken apart by hand. Examples: bushes, pulleys and wheels held by a key.
A guide only: the final choice depends on materials, temperatures, lengths and finishes.
Values from ISO 286-1:2010, ISO 286-2:2010. For reference only: the drawing and the standard govern.