Skip to content
Vectogap
Español

Ø50 H7/h6 fit

Ø50 H7/h6 is a clearance fit: the clearance runs from 0 to 41 µm.

Clearance fit

Limits

Deviations and limits of size of Ø50 H7/h6
ClassHole H7Shaft h6
Upper deviation+25 µm0 µm
Lower deviation0 µm-16 µm
Tolerance25 µm16 µm
Maximum size50.025 mm50 mm
Minimum size50 mm49.984 mm

Maximum size = nominal + upper deviation; minimum size = nominal + lower deviation; tolerance = upper − lower deviation. Maximum clearance = ES − ei; minimum clearance = EI − es.

Open Ø50 H7/h6 in the calculator

Typical use

Locational clearance fit: a snug fit for locating stationary parts that can still be assembled and taken apart by hand. Examples: bushes, pulleys and wheels held by a key.

A guide only: the final choice depends on materials, temperatures, lengths and finishes.

Values from ISO 286-1:2010, ISO 286-2:2010. For reference only: the drawing and the standard govern.