Ø50 H7/k6 fit
Ø50 H7/k6 is a transition fit: it goes from a clearance of 23 µm to an interference of 18 µm.
Transition fit
Limits
| Class | Hole H7 | Shaft k6 |
|---|---|---|
| Upper deviation | +25 µm | +18 µm |
| Lower deviation | 0 µm | +2 µm |
| Tolerance | 25 µm | 16 µm |
| Maximum size | 50.025 mm | 50.018 mm |
| Minimum size | 50 mm | 50.002 mm |
Maximum size = nominal + upper deviation; minimum size = nominal + lower deviation; tolerance = upper − lower deviation. Maximum clearance = ES − ei; minimum clearance = EI − es.
Open Ø50 H7/k6 in the calculatorTypical use
Locational transition fit, a compromise between clearance and interference where location accuracy matters. Assembled with a soft mallet or a light press. Examples: couplings, pulleys and gears on shafts.
A guide only: the final choice depends on materials, temperatures, lengths and finishes.
Values from ISO 286-1:2010, ISO 286-2:2010. For reference only: the drawing and the standard govern.