Ø12 H7/k6 fit

Ø12 H7/k6 is a transition fit: it goes from a clearance of 17 µm to an interference of 12 µm.

Transition fit

Limits

Deviations and limits of size of Ø12 H7/k6
ClassHole H7Shaft k6
Upper deviation+18 µm+12 µm
Lower deviation0 µm+1 µm
Tolerance18 µm11 µm
Maximum size12.018 mm12.012 mm
Minimum size12 mm12.001 mm

Maximum size = nominal + upper deviation; minimum size = nominal + lower deviation; tolerance = upper − lower deviation. Maximum clearance = ES − ei; minimum clearance = EI − es.

Open Ø12 H7/k6 in the calculator

Typical use

Locational transition fit, a compromise between clearance and interference where location accuracy matters. Assembled with a soft mallet or a light press. Examples: couplings, pulleys and gears on shafts.

A guide only: the final choice depends on materials, temperatures, lengths and finishes.

Values from ISO 286-1:2010, ISO 286-2:2010. For reference only: the drawing and the standard govern.