Ø16 H7/k6 fit
Ø16 H7/k6 is a transition fit: it goes from a clearance of 17 µm to an interference of 12 µm.
Transition fit
Limits
| Class | Hole H7 | Shaft k6 |
|---|---|---|
| Upper deviation | +18 µm | +12 µm |
| Lower deviation | 0 µm | +1 µm |
| Tolerance | 18 µm | 11 µm |
| Maximum size | 16.018 mm | 16.012 mm |
| Minimum size | 16 mm | 16.001 mm |
Maximum size = nominal + upper deviation; minimum size = nominal + lower deviation; tolerance = upper − lower deviation. Maximum clearance = ES − ei; minimum clearance = EI − es.
Open Ø16 H7/k6 in the calculatorTypical use
Locational transition fit, a compromise between clearance and interference where location accuracy matters. Assembled with a soft mallet or a light press. Examples: couplings, pulleys and gears on shafts.
A guide only: the final choice depends on materials, temperatures, lengths and finishes.
Values from ISO 286-1:2010, ISO 286-2:2010. For reference only: the drawing and the standard govern.