Skip to content
Vectogap
Español

Ø12 H7/h6 fit

Ø12 H7/h6 is a clearance fit: the clearance runs from 0 to 29 µm.

Clearance fit

Limits

Deviations and limits of size of Ø12 H7/h6
ClassHole H7Shaft h6
Upper deviation+18 µm0 µm
Lower deviation0 µm-11 µm
Tolerance18 µm11 µm
Maximum size12.018 mm12 mm
Minimum size12 mm11.989 mm

Maximum size = nominal + upper deviation; minimum size = nominal + lower deviation; tolerance = upper − lower deviation. Maximum clearance = ES − ei; minimum clearance = EI − es.

Open Ø12 H7/h6 in the calculator

Typical use

Locational clearance fit: a snug fit for locating stationary parts that can still be assembled and taken apart by hand. Examples: bushes, pulleys and wheels held by a key.

A guide only: the final choice depends on materials, temperatures, lengths and finishes.

Values from ISO 286-1:2010, ISO 286-2:2010. For reference only: the drawing and the standard govern.