Skip to content
Vectogap
Español

Ø50 H8/f7 fit

Ø50 H8/f7 is a clearance fit: the clearance runs from 25 to 89 µm.

Clearance fit

Limits

Deviations and limits of size of Ø50 H8/f7
ClassHole H8Shaft f7
Upper deviation+39 µm-25 µm
Lower deviation0 µm-50 µm
Tolerance39 µm25 µm
Maximum size50.039 mm49.975 mm
Minimum size50 mm49.95 mm

Maximum size = nominal + upper deviation; minimum size = nominal + lower deviation; tolerance = upper − lower deviation. Maximum clearance = ES − ei; minimum clearance = EI − es.

Open Ø50 H8/f7 in the calculator

Typical use

Close running fit for accurate machines at moderate speeds and journal pressures. Examples: shafts in plain bearings, gearboxes and pumps.

A guide only: the final choice depends on materials, temperatures, lengths and finishes.

Values from ISO 286-1:2010, ISO 286-2:2010. For reference only: the drawing and the standard govern.