Ø4 H8/f7 fit

Ø4 H8/f7 is a clearance fit: the clearance runs from 10 to 40 µm.

Clearance fit

Limits

Deviations and limits of size of Ø4 H8/f7
ClassHole H8Shaft f7
Upper deviation+18 µm-10 µm
Lower deviation0 µm-22 µm
Tolerance18 µm12 µm
Maximum size4.018 mm3.99 mm
Minimum size4 mm3.978 mm

Maximum size = nominal + upper deviation; minimum size = nominal + lower deviation; tolerance = upper − lower deviation. Maximum clearance = ES − ei; minimum clearance = EI − es.

Open Ø4 H8/f7 in the calculator

Typical use

Close running fit for accurate machines at moderate speeds and journal pressures. Examples: shafts in plain bearings, gearboxes and pumps.

A guide only: the final choice depends on materials, temperatures, lengths and finishes.