Skip to content
Vectogap
Español

Ø50 H7/u6 fit

Ø50 H7/u6 is an interference fit: the interference runs from 45 to 86 µm.

Interference fit

Limits

Deviations and limits of size of Ø50 H7/u6
ClassHole H7Shaft u6
Upper deviation+25 µm+86 µm
Lower deviation0 µm+70 µm
Tolerance25 µm16 µm
Maximum size50.025 mm50.086 mm
Minimum size50 mm50.07 mm

Maximum size = nominal + upper deviation; minimum size = nominal + lower deviation; tolerance = upper − lower deviation. Maximum clearance = ES − ei; minimum clearance = EI − es.

Open Ø50 H7/u6 in the calculator

Typical use

Force fit for parts that can take high stresses, or shrink fits where the pressing force needed would be impractical. Examples: rims on hubs and wheels on axles.

A guide only: the final choice depends on materials, temperatures, lengths and finishes.

Values from ISO 286-1:2010, ISO 286-2:2010. For reference only: the drawing and the standard govern.