Skip to content
Vectogap
Español

Ø30 H7/u6 fit

Ø30 H7/u6 is an interference fit: the interference runs from 27 to 61 µm.

Interference fit

Limits

Deviations and limits of size of Ø30 H7/u6
ClassHole H7Shaft u6
Upper deviation+21 µm+61 µm
Lower deviation0 µm+48 µm
Tolerance21 µm13 µm
Maximum size30.021 mm30.061 mm
Minimum size30 mm30.048 mm

Maximum size = nominal + upper deviation; minimum size = nominal + lower deviation; tolerance = upper − lower deviation. Maximum clearance = ES − ei; minimum clearance = EI − es.

Open Ø30 H7/u6 in the calculator

Typical use

Force fit for parts that can take high stresses, or shrink fits where the pressing force needed would be impractical. Examples: rims on hubs and wheels on axles.

A guide only: the final choice depends on materials, temperatures, lengths and finishes.

Values from ISO 286-1:2010, ISO 286-2:2010. For reference only: the drawing and the standard govern.