Ø50 H9/d9 fit
Ø50 H9/d9 is a clearance fit: the clearance runs from 80 to 204 µm.
Clearance fit
Limits
| Class | Hole H9 | Shaft d9 |
|---|---|---|
| Upper deviation | +62 µm | -80 µm |
| Lower deviation | 0 µm | -142 µm |
| Tolerance | 62 µm | 62 µm |
| Maximum size | 50.062 mm | 49.92 mm |
| Minimum size | 50 mm | 49.858 mm |
Maximum size = nominal + upper deviation; minimum size = nominal + lower deviation; tolerance = upper − lower deviation. Maximum clearance = ES − ei; minimum clearance = EI − es.
Open Ø50 H9/d9 in the calculatorTypical use
Free running fit where accuracy is not essential, or for high speeds, heavy journal pressures or large temperature changes.
A guide only: the final choice depends on materials, temperatures, lengths and finishes.
Values from ISO 286-1:2010, ISO 286-2:2010. For reference only: the drawing and the standard govern.