Ø50 H11/c11 fit
Ø50 H11/c11 is a clearance fit: the clearance runs from 130 to 450 µm.
Clearance fit
Limits
| Class | Hole H11 | Shaft c11 |
|---|---|---|
| Upper deviation | +160 µm | -130 µm |
| Lower deviation | 0 µm | -290 µm |
| Tolerance | 160 µm | 160 µm |
| Maximum size | 50.16 mm | 49.87 mm |
| Minimum size | 50 mm | 49.71 mm |
Maximum size = nominal + upper deviation; minimum size = nominal + lower deviation; tolerance = upper − lower deviation. Maximum clearance = ES − ei; minimum clearance = EI − es.
Open Ø50 H11/c11 in the calculatorTypical use
Very loose running fit, for parts with wide manufacturing tolerances or exposed to dirt, corrosion or large expansion. Examples: hinges, pivot pins and low-precision mechanisms.
A guide only: the final choice depends on materials, temperatures, lengths and finishes.
Values from ISO 286-1:2010, ISO 286-2:2010. For reference only: the drawing and the standard govern.