Skip to content
Vectogap
Español

Ø50 H11/c11 fit

Ø50 H11/c11 is a clearance fit: the clearance runs from 130 to 450 µm.

Clearance fit

Limits

Deviations and limits of size of Ø50 H11/c11
ClassHole H11Shaft c11
Upper deviation+160 µm-130 µm
Lower deviation0 µm-290 µm
Tolerance160 µm160 µm
Maximum size50.16 mm49.87 mm
Minimum size50 mm49.71 mm

Maximum size = nominal + upper deviation; minimum size = nominal + lower deviation; tolerance = upper − lower deviation. Maximum clearance = ES − ei; minimum clearance = EI − es.

Open Ø50 H11/c11 in the calculator

Typical use

Very loose running fit, for parts with wide manufacturing tolerances or exposed to dirt, corrosion or large expansion. Examples: hinges, pivot pins and low-precision mechanisms.

A guide only: the final choice depends on materials, temperatures, lengths and finishes.

Values from ISO 286-1:2010, ISO 286-2:2010. For reference only: the drawing and the standard govern.