Ø6 H7/p6 fit
Ø6 H7/p6 is an interference fit: the interference runs from 0 to 20 µm.
Interference fit
Limits
| Class | Hole H7 | Shaft p6 |
|---|---|---|
| Upper deviation | +12 µm | +20 µm |
| Lower deviation | 0 µm | +12 µm |
| Tolerance | 12 µm | 8 µm |
| Maximum size | 6.012 mm | 6.02 mm |
| Minimum size | 6 mm | 6.012 mm |
Maximum size = nominal + upper deviation; minimum size = nominal + lower deviation; tolerance = upper − lower deviation. Maximum clearance = ES − ei; minimum clearance = EI − es.
Open Ø6 H7/p6 in the calculatorTypical use
Locational interference fit: rigidity and alignment with the best location accuracy, without special bore pressure requirements. Examples: bearing bushes and dowel pins.
A guide only: the final choice depends on materials, temperatures, lengths and finishes.
Values from ISO 286-1:2010, ISO 286-2:2010. For reference only: the drawing and the standard govern.