Ø25 H7/p6 fit
Ø25 H7/p6 is an interference fit: the interference runs from 1 to 35 µm.
Interference fit
Limits
| Class | Hole H7 | Shaft p6 |
|---|---|---|
| Upper deviation | +21 µm | +35 µm |
| Lower deviation | 0 µm | +22 µm |
| Tolerance | 21 µm | 13 µm |
| Maximum size | 25.021 mm | 25.035 mm |
| Minimum size | 25 mm | 25.022 mm |
Maximum size = nominal + upper deviation; minimum size = nominal + lower deviation; tolerance = upper − lower deviation. Maximum clearance = ES − ei; minimum clearance = EI − es.
Open Ø25 H7/p6 in the calculatorTypical use
Locational interference fit: rigidity and alignment with the best location accuracy, without special bore pressure requirements. Examples: bearing bushes and dowel pins.
A guide only: the final choice depends on materials, temperatures, lengths and finishes.
Values from ISO 286-1:2010, ISO 286-2:2010. For reference only: the drawing and the standard govern.