Ø25 H7/g6 fit
Ø25 H7/g6 is a clearance fit: the clearance runs from 7 to 41 µm.
Clearance fit
Limits
| Class | Hole H7 | Shaft g6 |
|---|---|---|
| Upper deviation | +21 µm | -7 µm |
| Lower deviation | 0 µm | -20 µm |
| Tolerance | 21 µm | 13 µm |
| Maximum size | 25.021 mm | 24.993 mm |
| Minimum size | 25 mm | 24.98 mm |
Maximum size = nominal + upper deviation; minimum size = nominal + lower deviation; tolerance = upper − lower deviation. Maximum clearance = ES − ei; minimum clearance = EI − es.
Open Ø25 H7/g6 in the calculatorTypical use
Sliding fit: the parts are not meant to run freely, but they move and turn easily and locate accurately. Examples: sliding gears, plungers and guides.
A guide only: the final choice depends on materials, temperatures, lengths and finishes.
Values from ISO 286-1:2010, ISO 286-2:2010. For reference only: the drawing and the standard govern.