Skip to content
Vectogap
Español

ISO 286 tolerance and fit calculator

Enter a nominal size and a hole class, a shaft class or both to get the limit deviations, the limits and, for a pair, the fit.

Hole
Shaft
ClassH7g6
Upper deviation+21 µm-7 µm
Lower deviation0 µm-20 µm
Tolerance21 µm13 µm
Maximum size25.021 mm24.993 mm
Minimum size25 mm24.98 mm

Clearance fit

Maximum clearance: 41 µm

Minimum clearance: 7 µm

A negative clearance is an interference.

Calculated in your browser: the values you enter are never sent anywhere.

How it works

A tolerance class is a letter and a number. The letter, the fundamental deviation, places the tolerance zone relative to the nominal size; the number, the standard tolerance grade IT, sets its width. Capital letters are holes and lowercase letters are shafts.

In a fit, the clearance is the hole size minus the shaft size. If it is always positive the fit has clearance; if it is always negative, interference; if it can be either, it is a transition fit.

Rule

Maximum size = nominal + upper deviation; minimum size = nominal + lower deviation; tolerance = upper − lower deviation. Maximum clearance = ES − ei; minimum clearance = EI − es.

Worked example

Ø25 H7/g6: H7 gives ES = +21 µm and EI = 0; g6 gives es = −7 µm and ei = −20 µm. Maximum clearance = 21 − (−20) = 41 µm and minimum clearance = 0 − (−7) = 7 µm. Both are positive, so it is a clearance fit.

Frequent fits

Each fit has its own page with the limits, the fit type and its typical use.

Values from ISO 286-1:2010, ISO 286-2:2010. For reference only: the drawing and the standard govern.